Telescope and dome control system for operations at the OGS
A. Starting up the telescope and pointing an object
-
START voltage control by pushing the button placed in the box on the left of the control PC.
-
Log in in the control PC: Pressing upper right button on the screen, log in window will appear.
(user and password can be consulted on the control room manual)
-
Turn on the dome by pressing ON button on the DOME window.
-
In order to open shutters, push OPEN button of the corresponding shutter. In case you want to stop it, press STOP. Shutter status will be ‘UNKNOWN’.
-
To turn on the telescope, press ON on the TELESCOPE window. If the square on the right of the INIT button is not green-coloured the telescope should be initalized. If it is the case, press INIT.
-
To open the mirror covers, push OPEN button in the DEW-CAP window.
-
Introduce the coordinates of the object to observe and press SLEW.
-
Press AUTO from DOME if the dome following the telescope is wanted.
-
To stop both telescope and dome push STOP on the TELESCOPE window and DOME window respectively.
B. Stopping the telescope and parking it on the zenith position.
-
Stop the telescope and the dome by pressing STOP button in the TELESCOPE and DOME windows.
-
Press CLOSE button in the DEW-CAP window to close mirror covers.
-
Press POSITS in the TELESCOPE window.
-
A new window will appear (PREDEFINED POSITIONS). Select ZENITH option by pushing POSIT button on the right.
-
In the MECHANICAL COORDINATES window, press SLEW.
-
Close shutters pressing CLOSE button in the aproppiate window.
-
Turn off the telescope and the dome by pushing OFF in the TELESCOPE window and also in the DOME window.
-
STOP voltage control by pressing the button on the box placed on the right of the control PC.
-
Log off in the control computer: a window with the ‘logoff’ option will appear when the upper right button on the secreen is pressed.